2(18r)S1 15. White Paper © 2011 Cisco and/or its affiliates. Supervisor Compatibility C6800-SUP6T C6800-SUP6T-XL VS-S2T-10G VS-S2T-10G-XL. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxxxxxxxxxx . 5Ghz per core. 40 206. Step 2 Click New Deployment to create a new deployment profile. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1741E42N. Mod Sub-Module Model Hw. 00 1. Can I mix a Cisco Supervisor Engine 2T with Sup720-10G in a VSS-configured system? A. VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP vs-s2t-10g-xl-rf The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. Doc Preview. We have purchased an additional SUP module to install into each switch so that we can create a quad SUP VSS. Cisco announces the end-of-sale and end-of life dates for the Cisco Catalyst 6500 Series Supervisor Engine 32, plus the Cisco Catalyst 6500 and Cisco 7600 Series Supervisor Engine 32 Bundles. The supervisor is VS-SUP2T-10G and the tranceivers are X2-10GB-LX4 and X2-10GB-SR, both of these tranceivers are on different uplinks to other SWITCH. 13 pounds : Product Dimensions 15. 0 Helpful. One VSS pair has more C6800-32P10G that the other. Log In. Component. Reza Sharifi. 1200 ports scale support on Sup2T —See this publication:vs-c6509e-sup2t-rf Cat ChassisFanTray+Sup2T;IP SvcsONLY incl VSS REMANUFACTURED. I installed Sup2T engine on 7606-x chassis. Consider switching to something new: The Cisco Catalyst 9400 Series Switches offer greater speed, performance and security. 6 Tbps wired switching capacity, with 8 Bpps of forwarding performance is unleashed with Cisco Catalyst 9600 Series. The Cisco Catalyst ® 6800 Family Switches offer a 8-port 40-Gigabit Ethernet module to serve a variety of high-bandwidth needs for the next-generation enterprise. 2 Other 8 Distributed Forwarding Card. 2 Release Notes for Cisco IOS Release 15. The two supervisor engines must match exactly. *May 27 06:47:53. SPA. module 7 device-2 temperature: 41C. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. DRAM. and becareful with: • WS-X6148A-RJ-45, WS-X6148-FE-SFP, and WS-X6148A-GE-TX. VS-10G is the multi functional smart VARILIMIT with various output options such as digital signal output, analog signal output, motion control and multi preset function. Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL Cisco Catalyst 6500 Series Supervisor Engine 2T Power Supply Compatibility * Indicates EoS Power Supply AC: 1400W, 950W* DC: 950W* AC: 2700W DC: 2700W AC: 2500W*, 3000W, 4000W, 6000W, 8700W DC: 2500W, 4000W,. 0 12. 1(2)SY14—14. Catalyst 6513. WS-C6509-E modules installed are: 1 24 CEF720 24 port 1000mb SFP WS-X6724-SFP 2 8 DCEF2T 8 End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. Console ports. Mod Sub-Module Model Serial Hw Status Data confidentiality and integrity: The Cisco Catalyst 4500E Supervisor Engine 7L-E supports line-rate 10G MACsec encryption based on IEEE 802. VS-C6509E-S720-10G Catalyst Chassis+Fan Tray+Sup720-10G; IP Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on. VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories ; End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories ; EOS/EOL for. Cisco OneX Converter Module 5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1731APXD 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G SAL1731APZY 8 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1730AFG9. It also features a new, separate, out-of-band Connectivity Management Processor (CMP) CPU. Product Overview. i think this need to be port-channel 2 in the secondary VSS. VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - VS-S720-10G-3C Cat 6500 Supervisor 720 with 2 ports 10GbE and MSFC3 PFC3C VS-S2T. 652); SFP-10G-LR, supports 10 km on standard single-mode fiber (SMF, G. Solved! Go to Solution. Both switches need to run the same IOS version (check with 'sh ver'). 10 WS-SUP720 Supervisor Engine 720 with PFC3A daughter card andThis PDN was published on 10/31/2014 and lists all parts with the LTB date of 07/31/2015. Could anybody tell me when the dates of Eol of these two modules are?Software compatibility. The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. Hello Friends, we have WS-C6513-E ( IOS 15. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories. If you have a monitoring system e. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. Refurbished VS-S2T-10G Supervisor Blade for Catalyst 6500 and 7600 Chassis Switches with Warranty X2 Modules shown in picture not included but available separately The Cisco® Catalyst® 6500 Supervisor Engine 2T is the newest addition to the family of supervisor engines. Mod Ports Card Type Model Serial No. 1 VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 21 days $ 28,000. 2 people had this problem. The Gigabit Ethernet modules serve campus and data center networking requirements in enterprise, commercial, and service provider environments. This publication describes how to check the status of the voltage termination (VTT) modules and clock modules and describes how to remove and install the modules on the following Catalyst 6500 series switches and Cisco 7600 series routers: Catalyst 6500 Series Switches. e 1. The Gigabit Ethernet Copper. Hall of Fame. 4 Tbps bandwidth per slot. 6 Tbps in wired switching capacity, with up to 6. 2(50r)SYS 15. VS-S720-10G-3C= Cat 6500 Supervisor 720 with 2 x 10GbE and 3x1GE MSFC3 PFC3C-VS-C6513-S720-10G. 1(2)SY16—20 February 2020 • Release 15. Solved: Hi, We've just invested in a pair of Sup2Ts to upgrade a Sup720 6509 chassis but I'm unsure exactly how the management port (s), aka the Connectivity Management Processor (CMP), should be configured (and. Caveats Resolved in Catalyst 6500 Supervisor Engine 2T ROMMON Software Release 12. Catalyst 6500 10 Gigabit Ethernet For Sup2T WS-X6908-10G-2T-RF The Cisco Catalyst 6900 Series 8-port 10 Gigabit Ethernet Fiber Module is the first 10 Gigabit Ethernet module that supports Cisco TrustSec and layer 2 encryption in hardware to enable IEEE 802. module 7 asic-5 temperature: 54C. comsupervisor engine Sup6T Sup2T Get more information. BTW, Reza mentions the sup and DFC XL feature needs to match, i. The Cisco Catalyst ® 6500 Series Switches offer a variety of 10 Gigabit and Gigabit Ethernet modules which work in conjunction with the new Catalyst 6500 Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL) to serve different needs in the campus and data center for enterprise, commercial, and service provider customers. 5(1)SY2, page 52 † New Features in Release 15. IOS is 15. 07-02-2012 08:42 AM. VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4. 1 12. Cisco OneX Converter Module5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1731APXD 6 5 Supervisor Engine 2T 10GE w/ CTS (CSSO VS-SUP2T-10G SAL1731APZY 8 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1730AFG9. QTY. Switch Model : Cisco C6905-E. 098a. 5cd9. The documentation set for this product strives to use bias-free language. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. Find Cisco VS-S2T-10G-XL best price and specification, and more Cisco Catalyst 6500 Series Bundle: VS-S2T-10G-XL, delivering high speed and reliable network connections for you need. Name VS-S2T-10G VS-S2T-10G-XL IPv4 routing In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** IPv6 routing In hardware Up to 390 Mpps ** In hardware Up to 390 Mpps ** L2 bridging In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** MPLS MPLS in hardware to enable use of Layer 3 VPNs and EoMPLS tunneling. Feature VS-S2T-10G VS-S2T-10G-XL Port security Yes Yes IEEE 802. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. Cisco Supervisor Engine 2T is shipped with a 2-GB DRAM module by default. このファミリには、Cisco Catalyst 6800 32 ポート、16 ポート、および 8 ポートの 3. Conditions: reload. 00BOM. (Don’t be confused by the fact that the old Supervisor 2 went end-of-sale on 2007. The versatile Cisco Catalyst 6500-E Series Chassis is ideal for addressing high-performance, high- port-density Fast Ethernet, Gigabit Ethernet, and 10 and 40 Gigabit Ethernet applications in all parts of the. Only WS-X6904-40G-2T is being replaced and not the C6800-32P10G module. WS-C6509-E modules installed are: 1 24 CEF720 24 port 1000mb SFP WS-X6724-SFP 2. See all 5 - listings for this product. g SolarWinds NPM, you can look at the CPU and memory history before and after. 00. Compatibility matrix which eludes the CVR-X2-SFP10G module is compatible with the VS-S2T-10G and SFP-H10GB-CU5M but only if the SFP-H10GB-CU5M is version 2. Cat6k - Sup2T - DHCPv6 control packets snooped by MLD when forwarded over VPLS circuit. 5164 5 5 VS-S2T-10G Line Card Compatibility jamaludeen_s Beginner Options 10-01-2017 06:38 AM - edited 03-08-2019 12:13 PM Hi, I am configuring C6807 series. e514. 5(1)SY5. VS-SUP2T-10G. Cisco VS-S2T-10G Datasheet PDF Download the datasheet of Cisco VS-S2T-10G. It has exceeded normal operating temperature range. 50. Dear, Cisco announced EOL for ws-x6148A-GE-45AF linecard and proposed WS-X6148E-GE-45AT. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32 27-Jul-2017. PID Runtime (ms) Invoked uSecs 5Sec 1Min 5Min TTY Process. The MSFC3 is an integral part of the Supervisor Engine 720, providing high performance, multilayer switching and routing intelligence. (Acti VS-SUP2T-10G SAL1552Z77B 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1551YMH0. module 7 asic-4 temperature: 64C. In VSS mode, unsupported switching modules remain powered off. WS-C6509-E Datasheet Get a Quote Overview The 9-slot Cisco Catalyst 6509-E Switch provides high port densities that are ideal for many wiring closet, distribution, and core network as well as data center. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. Also, remember that this is just end of sales and Cisco will still support the existing cards for a few more years. 本文档介绍在虚拟交换系统(VSS)模式下使用Supervisor 2T和双宿主Cisco Catalyst 6800即时接入交换机(FEX)的Cisco Catalyst 6500系列交换机上的分步服务中软件升级(ISSU)过程。According to this he saw the supervisor modules VS-SUP2T-10G a bit high and started to worry: module 5 outlet temperature: 39C. 46W from on 6000W power supply. 09-07-2021 03:08 AM - edited 09-07-2021 03:09 AM. I recall, the only 67xx card that will not work with a sup2T is the 6708, because it comes with a DFC3 that cannot be replaced (with the DFC4 or a CFC). 0f9c. Step 3 Ensure that the pre-requisites mentioned in the Before you Begin page are satisfied and then click Begin . Hello, I have a 6506E chassis that I am upgrading to a pair of SUP2Ts. 00 Get Discount: 3: 7606S-SUP2TXL-P. Tray+Sup720-10G; IP Base ONLY incl. K. New here?Bias-Free Language. The two supervisor engines must match exactly. I have this problem too. 611: %LICENSE-6-RECOVERED: The IOS license storage on this device was recovered. Solved: Hi. 15 512. Beginner. That is correct. As far as we know that we cannot run ISSU, thus we tried with an upgrade via changing the boot parameter. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. SPA. We have no test 6500 to install the replacement supervisor engine to and put on the correct IOS and config in advance of the replacement. e514. One of them is a supervisor module called Supervisor 2T (products VS-S2T-10G and VS-S2T-10G-XL) which practically replaces the previous Sup720 family variants. Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エンジン(FE)で ELAM を実行します。L2 FE データ バス. Offering flexible port-speed configurations, the switch supports 48 ports of 100M/1/2. We are ready to help with your network equipment and services needs. . 11-17-2016 05:43 AM - edited 03-08-2019 08:11 AM. . End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6816 10 GE Line Card and Select Accessories 13-Feb-2017. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. 2-SY(MD) instead?View online or download PDF (158 KB) Cisco Supervisor Engine 2T, VS-S2T-10G-XL= Data Sheet • Supervisor Engine 2T, VS-S2T-10G-XL= network switch modules PDF manual download and more Cisco online manualsBuy or Renew. 5. Catalyst 6503-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community. Cat ChassisFanTray+Sup2T;IP SvcsONLY incl VSS REMANUFACTURED. 0f9c. 1(2)SY11 Ok1 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1618BM8W 2 16 CEF720 16 port 10GE WS-X6716-10GE SAL16159VEP. Cisco VS-S2T-10G Datasheet Cisco VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 VS-S2T-10G Cisco VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 Buy Now Powered by TCPDF (Title: Cisco VS-S2T-10G Datasheet Author: GenuineModules. 423. In VSS mode, unsupported switching modules remain powered off. Although not mandatory, we recommend that you install a second 2-GB DRAM module when installing VS-F6K-PFC4XL=. MEM-SUP2T-2GB Catalyst 6500 2GB Memory for Sup2T and Sup2TXL. Replacing bad 6807-xl vs-sup2t-10g mpkohan69. The front panel is labeled WS-X6708-10GE. 12-04-2011 08:14 PM - edited 03-04-2019 02:31 PM. For information about X2 modules, see the Cisco 10GBASE X2 Modules data sheet:. Thanks for your comment! Hi I'm confused about what is the best procedure to replace a failed SUP2T-10G on VSS because I founded 2 ways: 1° - Replace the failed SUP -Copy the Same IOS on the new SUP -Configure the VSS: switch virtual domain 100 switch 1 priority 200 !Hi experts, I have two 6500 in VSS. 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL1643QYRY. 5/5/10G BASE-T on the downlinks. When I shutdown the chassis and install the SUP2T they never power up. WS-X6708-10G-3C and WS-X6708-10G-3CXL are the orderable product IDs. 5 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1639NJ7U Mod MAC addresses Hw Fw Sw Status 1 6073. The answer, I believe, is yes. Leo Laohoo. Hello all experts! No matter how I search on the internet about "VS-SUP2T-10G", there was no datasheet. Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY. Canon Perdido, Suite 100 Santa Barbara, CA 93101Same bug for VS-SUP2T-10G on Cisco 6807XL VSS version 15. I have this problem too. MSFC3. bootdisk: (active) and slavebootdisk: (standby): 1-GB internal flash memory Feature VS-S2T-10G VS-S2T-10G-XL Port security Yes Yes IEEE 802. Before I configured VSS all modules working ok on both chassis, Below is show module output. Feature WS-SUP720-3B WS-SUP720-3BXL VS-S720-10G-3C* VS-S720-10G-3CXL* Layer-3 Classification and Marking Access Control Entries (ACEs) 32 K dedicated for QoS 32K dedicated for QoS 32 K dedicated for QoS 32K dedicated for QoS Aggregate Rate-Limiting Location Ingress port or VLAN and egress VLAN or Layer-3 port Ingress port or VLAN Tray+Sup720-10G; IP Base ONLY incl. The Cisco Catalyst 4500E Supervisor Engine 7L-E builds on the success of its predecessor,. PRODUCT IS NEW AND IN OPEN CONDITION. To upgrade from VS-S2T-10G to VS-S2T-10G-XL, remove VS-F6K-PFC4= from the corresponding supervisor engine and install VS-F6K-PFC4XL=. I have 3 pairs of 6807 VSS switches. Cisco Nexus 7000 Series Supervisor2 Module. 2(50r. October 31, 2019 End-of-Sale Date: HW, Accessory To upgrade from VS-S2T-10G to VS-S2T-10G-XL, remove VS-F6K-PFC4= from the corresponding supervisor engine and install VS-F6K-PFC4XL=. €5€€€ 5€ Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G€ €€€€ SAL15056BKR Sup2T の場合、Eureka という内部コード名が設定されたレイヤ 2(L2)フォワーディング エン ジン(FE)で ELAM を実行します。L2 FE データ バス(DBUS)に、L2 およびレイヤ4 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1941QX54 5 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL1825UZLA. Note The 1-Gigabit Ethernet ports and the 10-Gigabit Ethernet ports have the same QoS port architecture (2q4t/1p3q4t) unless you disable the 1-Gigabit Ethernet ports with the platform qos 10g-only global configuration command. 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories Milestone Definition Date End-of-Life Announcement Date The date the document that announces the end-of-sale and end-of-life of a product is distributed to the general public. It supports 80 Gbps with your sup2T. interface port-channel 1 change it 2 and remove the 1 form the standby one. 0 C6807-XL-S2T-BUN Chassis+Fan Tray+ Sup2T+2xPower Supply; IP Services ONLY N/A 39 days No 2 -- 0 -- 1. VS-SUP2T-10G. 10/31/2014. Is the following upgrade process correct? 1. Customers with active service contracts will continue to receive support from the. Make sure to start with the VSS, both the devices has same model and. VS-C6509E-SUP2T. Cisco Supervisor Engine 2T is shipped with a 2-GB DRAM module by default. Network Management Check the supervisor engine data sheet Physical. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. SPA. Find answers to your questions by entering keywords or phrases in the Search bar above. $88,000. Contact Cisco. I have two cisco 6509-E catalyst chassis with Dual VS-SUP2T-10G Supervisor Engineen each. VS-SUP2T-10G-MSFC5 Supervisor Engine 2T with MSFC5 daughter card. Chinese;. That is correct. 5 5 Supervisor Engine 720 10GE (Active) VS-S720-10G SAL1323RSW8. I have this problem too. bin. One of them is a supervisor module called Supervisor 2T (products VS-S2T-10G and VS-S2T-10G-XL) which practically replaces the previous Sup720 family variants. The CISCO Catalyst VS-SUP2T-10G VS-F6K-PFC4 represents one item of our extensive telecommunications portfolio, which includes products from many of the world’s key OEM’s, including Ericsson, Siemens, Nortel, Nokia and Marconi. 1 Ok. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. module 7 asic-4 temperature: 64C. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard. 2(1)SY5, supervisor- VS-SUP2T-10G, VSS running) we are planning to install C6800-8P10G Interface Module. Here are the details below: Here’s are current supervisors & code version: VS-SUP2T-10G & VS-F6K-PFC4 IOS Version: s2t54 Softwa. Does anyone know how to enable it? comments sorted by Best Top New Controversial Q&A Add a Comment blacksheep5405 • Additional comment actions. 7 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL202801YG. EOS/EOL for 64MB Compact. I need to copy an image from USB to a SUP2T but the USB port appears to be disabled. 1 Ok 7 Centralized Forwarding Card WS-F6700-CFC SAL12372XVF. ) The sup720 is, more-or-less, a sup2 with a better (720 Gbps vs. Everything work fine. 0(1)SY7a ) with VS-SUP2T-10G. 54 10. $6,500. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible >> with Supervisor DFC. 02-23-2016 12:48 AM - edited 03-08-2019 04:41 AM. my question is that if this is the correct behavior on 6500 ??. Switching Modules. 46W from both 6000W supplies, and if one of the them fails, it will still use 2504. 5cd9. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. 10-08-2019 08:17 AM. 3 CPU Daughterboard VS-F6K-MSFC5 SAL1930KNDW 3. Mod Online Diag Status---- -----1 PassSup2T#show module 5 Mod Ports Card Type Model Serial No. Would anyone be able to confirm that the below line card works with our T2 supervisors? The original ones WS-X6704-10GE= are end of life and can no longer be ordered. A faster CPU and expanded memory compared to the first-generation Sup1 module. 2(1)SY1 to build VSS is ok ? Or who can give me suggest version to build VSS. Chinese; EN US; French; Japanese; Korean; PortugueseThese are based on the Supervisor Engine 2T and the Supervisor Engine 720-10G. VS-SUP2T-10G= Sup2T Baseboard spare: There is no replacement product available. Max. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G. 54 10. Catalyst 6504-E. 6 24 CEF720 24 port 1000mb SFP WS-X6724-SFP SAL1317P297. 56. This document is Cisco Public Information. 60. WS-C6509-E modules installed are: 1 24 CEF720 24 port 1000mb SFP WS-X6724-SFP . you can run a show mod and you will see the serial numbers for the modules are different than the chassis. SY3. 00. In a system configured for VSS, this translates to a system capacity of up to 22. Options. This card can be acquired and installed by yourself with no problems. module 5 asic-1 temperature: 51C. Hi there VSS sups , you cant do seamless going to VSS from standard your going to take hits no matter what way , reason being theres a conversion section where it turns the switches into VSS capable , this causes a reboot , no way around it part ofEnd-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles & Accessories 17-Nov-2022. The upgrade has been rolled back for now. 6 VS-SUP2T-10G supervisor CEF Router# This example shows how to display VLAN information: Router# show platform hardware capacity vlan VLANs: 4094 total, 10 VTP, 0 extended, 0 internal, 4084 free Router# Module Status Monitoring The supervisor engine polls the installed module s with Switch Communication Protocol (SCP) messages. 30 points of limit switches output; Max. Global Price in USD. All forum topics; Previous Topic; Next Topic; 7 Replies 7. switch 2 module 5: switch 2 module 5 power-output-fail: OK switch 2 module 5 outlet temperature: 40C switch 2 module 5 inlet temperature: 26C switch 2 module 5 device-1 temperature: 34C switch 2 module 5 device-2 temperature: 36C switch 2 module 5 asic-1 temperature: 64C switch 2 module 5 asic-2. Cat 6500 Sup 2T with 2x10GbE and 3 x 1GbE with MSFC5 PFC4XL. The four Supervisor Engine Model Numbers supporting VSS are: VS-S2T-10G VS-S2T-10G-XL VS-S720-10G-3C VS-S720-10G-3CXL Table 1. The VS-C6509E-SUP2T Cisco Catalyst Manageable Switch offers advanced security features to protect the network from various security threats. Hello community, Hi have a Cisco Catalyst 6807-XL and some line cards as supervisor VS-SUP2T-10G, a module C6800-32P10G, a module WS-X6904. Note : the origin-id is prepend to syslog messages sent to REMOTE hosts, so it will. Itprice. The two supervisor engines must match exactly. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all. 1. module 7 RP outlet temperature: 43C. With SUP720 and WS-X6716-10GE (DFC3) I. pdf - F4F1AS6152AC07B. Customers with active service contracts will continue to receive support from the Cisco Technical Assistance Center (TAC) as shown in Table. Operating temperature. Switching Modules. wrote: Im facing huge packet loss with only longer distances affected. VSS mode does not support 61xx switching modules. Note that the L2 FE data bus (DBUS) contains original header information before the L2 and L3 lookup and the result bus (RBUS) contains the results. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. 4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19038DU0. (Sup VS-SUP2T-10G) Reviewed in the United States on 9 September 2012. 1. 0. Pages 14. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17110FMR 5 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL12469V08. 8 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL16138MPH Mod MAC addresses Hw Fw Sw Status--- ----- ----- ----- ----- 8 588d. EOS/EOL for 64MB Compact. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Cisco Catalyst 9606R chassis is hardware ready to support up to 25. 98 x 14. 5 5 Supervisor Engine 2T 10GE w/ CTS. Mod MAC addresses Hw Fw Sw StatusExplorer. 3 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6848-GE-TX SAL19058UN3. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or. The password-recovery process will only work if the line card works stand alone. There's also a VS-SUP2T supervisor card. 0 12. We have no test 6500 to install the replacement supervisor engine to and put on the correct IOS and config in advance of the replacement. 2 OkVS-SUP2T-10G が稼動する Catalyst 6500 シリーズスイッチではライセンスのインストールは必要ありませんが、同様な実装の他の機器と異なり、以下の様に、'show license' コマンドが入力でき出力も表示されます。 この動作は不具合ではありませんので、出力等に関して調査を行う必要はありません。5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17194J7J. For a quote or to request more information, please complete the form. 7 Centralized Forwarding Card. Default Control Plane Policy on Catalyst 6500/Sup2T and Catalyst 6880 Configuration Example ;VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 - S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA . Post Reply Getting Started. Cisco Catalyst 6500 4-Port 10 Gigabit Ethernet Fiber Module. 0. 66. Find software and support documentation to design, install and upgrade, configure, and. Scott Fella. It has 1G fiber and 1/10G fiber options, as well as several 10/100/1000 and 100/1000/2. Community. 39. Mod Ports Card Type Model Serial No. 206. 8aff 1. The Cisco Nexus 7000 Series Supervisor2 (Sup2) Module (Figure 3) is based on a quad-core Intel Xeon processor with 12 GB of memory and scales the control plane by harnessing the flexibility and power of the quad cores. SPA. 0(1)SY2 Ok. Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. C6880-X-LE. 11 slot chassis * 160 Gbps= 1760 i. However, from the second link I see a limit of 256K IPv4 routes for SUP2T and PFC4, instead SUP2T XL and PFC4 XL can support. 00. So, I think, the Q&A is correct. Reading through the hardware guide (Jan 19, 2018) doesnt look like the second port is enabled yet. As the 1G and 2 x 10G ports share the total 20G bandwidth points on the SUP2T, if both 10G ports are used for VSL, the 1G ports can not. EOS/EOL for 64MB Compact. 1ae with no additional latency. 5(1) sy4, we run now on version 15. 02-06-2013 07:40 AM - edited 03-07-2019 11:33 AM. The Cisco ® Catalyst ® 4500E Supervisor Engine 7L-E (Figure 1) is an enterprise-class borderless campus access and price/performance aggregation supervisor engine designed to provide 520 Gbps per system with E-Series chassis. $5,500. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. In VSS mode, unsupported. WS-X6816-10G-2T: 16-port 10 Gigabit Ethernet Fiber Module with DFC4 (Figure 1) and WS-X6816-10G-2TXL: 16-port 10 Gigabit Ethernet Fiber Module DFC4XL (Figure 1) Backplane connection: Connects to the switch fabric using dual full-duplex 20 Gbps switch fabric channels (40 Gbps total). module 7 device-1 temperature: 40C. The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance, better scalability, and enhanced hardware-enabled features. ROM: System Bootstrap, Version 12. 60.